Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
1.
Mater Horiz ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38623069

RESUMO

Vacancies, as well as their derivatives, usually play a crucial role in many essential properties of materials. However, they always behave erratically, especially under universal thermal vibration, and are therefore difficult to accurately locate. Until now, the lack of an accurate and flexible method for locating and identifying vacancies has hampered the development of relative fields. In this paper, we present a new method to solve this problem. The strategy is to target the atomic cage enwrapping vacancies instead of the vacancies themselves. The core of the method is a time-averaged atomic volume spectrum (TAVS). The key to this method is to identify atoms using time-averaged rather than transient atomic volume, thereby simultaneously denoising intrinsic thermal vibration and avoiding vacancy migration jump. Using this method, we have succeeded for the first time in obtaining the panoramic maps of spontaneously trapped defects in quenched and annealed face-centered cubic aluminum and even the instantaneous images of a steady trapping process. All characteristics of each trapped vacancy, including location, dimension, volume and morphology, as well as aggregate statistical data such as vacancy amount and concentration, can be completely and accurately obtained. Furthermore, these first maps of defects (vacancies) revealed some surprising and interesting phenomena for future exploration. In conclusion, this method provides not only a means of locating and catching vacancies, but also a strategy for identifying and characterizing vacancies. On the basis of its successful application in FCC Al, the TAVS method can be easily extended to other systems as well.

2.
Front Surg ; 11: 1290574, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38645506

RESUMO

We report three patients with screw-in lead perforation in the right atrial free wall not long after device implantation. All the patients complained of intermittent stabbing chest pain associated with deep breathing during the implantation. The "dry" epicardial puncture was utilized to avoid hemopericardium during lead extraction in the first case. The atrial electrode was repositioned in all cases and replaced by a new passive fixation lead in two patients with resolution of the pneumothorax or pericardial effusion. A literature review of 50 reported cases of atrial lead perforation was added to the findings in our case report.

3.
Anal Chim Acta ; 1294: 342292, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38336413

RESUMO

BACKGROUND: Hypochlorous acid (HClO) is an important biomarker for inflammation, cardiovascular disease, and even cancer. It is of great significance to accurately monitor and quantitatively analyze the fluctuations of HClO to better understand their physiological functions. Traditional HClO detection methods such as high-performance liquid chromatography (HPLC), and mass spectrometry are preferred, but are costly and unsuitable in vivo. Near-infrared (NIR) fluorescence imaging has the advantages of high sensitivity, high temporal and spatial resolutions, minimal autofluorescence, and deep tissue penetration, which facilitates its application in biological systems. Therefore, the development of sensitivity and simple NIR fluorescence monitoring HClO methods in vivo and in vitro is essential and desirable. RESULTS: Herein, we present a NIR probe NOF3 by integrating the rhodamine scaffold and HClO-triggered moiety for the real-time detection of HClO in vitro and in vivo. NOF3 reacts with the HClO and releases the NOF-OH fluorophore of emitted signals at 730 nm, which is in the NIR region. The designed probe detected concentrations of HClO ranging from 0 to 17 µM with a low detection limit of 0.146 µM, presenting excellent sensitivity and selectivity toward HClO over other species. NOF3 manifests significantly turn-on NIR fluorescent signals in response to HClO concentration, which makes it favorable for monitoring dynamic HClO distribution in vivo. We exemplify NOF3 for the tracking of endogenously overexpressed HClO distribution in RAW 264.7 cells, and further realize real-time in vivo bioimaging of HClO activity in inflammation mice. SIGNIFICANCE: The facile NIR NOF3 probe was successfully applied to visualize endogenous and exogenous HClO in living cells and mice. This study provides not only an effective tool for spatial and temporal resolution HClO bioimaging in vivo but also possesses great potential for use in future research on HClO-related biology and pathology.


Assuntos
Ácido Hipocloroso , Xantenos , Camundongos , Animais , Ácido Hipocloroso/análise , Rodaminas/química , Corantes Fluorescentes/química , Inflamação/diagnóstico por imagem
4.
Med Sci Monit ; 30: e942747, 2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38400538

RESUMO

BACKGROUND International studies have shown that use of a subcutaneous implantable cardioverter defibrillator (S-ICD) could reduce lead-related complications while maintaining adequate defibrillation performance; however, data from the Chinese population or other Asian groups are limited. MATERIAL AND METHODS SCOPE is a prospective, multicenter, observational cohort study. Two hundred patients with primary prevention indication for sudden cardiac death (SCD), who are candidates for S-ICD, will be enrolled. From the same population, another 200 patients who are candidates for transvenous implantable cardioverter defibrillator (TV-ICD) will be enrolled after being matched for age, sex, SCD high-risk etiology (ischemic cardiomyopathy, and non-ischemic cardiomyopathy, ion channel disease, and other) and atrial fibrillation in a 1: 1 ratio with enrolled S-ICD patients. All the patients will be followed for 18 months under standard of care. RESULTS The primary endpoint is proportion of patients free from inappropriate shock (IAS) at 18 months in the S-ICD group. The lower 95% confidence bound of the proportion will be compared with a performance goal of 90.3%, which was derived from the previous meta-analysis. The comparisons between S-ICD and TV-ICD on IAS, appropriate shock, and complications will be used as secondary endpoints without formal assumptions. CONCLUSIONS This is the first prospective multicenter study focusing on the long-term performance of S-ICD in a Chinese population. By comparing with the data derived from international historical studies and a matched TV-ICD group, data from SCOPE will allow for the assessment of S-ICD in the Chinese population in a contemporary real-world implantation level and programming techniques, which will help us to further modify the device implantation and programming protocol in this specific population in the future.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Desfibriladores Implantáveis , Humanos , Estudos Prospectivos , Resultado do Tratamento , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/epidemiologia , Prevenção Primária , China
6.
Phys Chem Chem Phys ; 25(44): 30516-30524, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37921640

RESUMO

MgO is a crystalline solid with significant practical and theoretical value in many fields. Brillouin scattering has long been regarded as a reliable method for accurately measuring the elasticity and photoelasticity of crystals; however, its practical application in photoelasticity has been stagnant. In this paper, three independent photoelastic constants of MgO have been measured for the first time by polarized Brillouin scattering spectroscopy and we have defined a scattering factor containing three photoelastic constants to connect with the Brillouin peak intensity. Accordingly, the ratios of |p11/p44| = 2.87 (1), |p12/p44| = 0.53 (2), and |p12/p11| = 0.18 (1) were accurately determined by comparing the intensities of transverse and longitudinal acoustic modes within the same spectrum. Then, a standard sample of CaF2 crystals was adopted to calculate the corresponding peak intensity of MgO to achieve the absolute values (|p44| = 0.085 (1), |p11| = 0.244 (4) and |p12| = 0.045 (3)). Finally, all three constants were confirmed to be negative. These first-hand Brillouin scattering results can eliminate the long-standing discrepancies of the photoelastic constants of MgO. A standard process for the simultaneous measurement of elasticity and photoelasticity through Brillouin scattering was also constructed.

7.
ACS Appl Mater Interfaces ; 15(41): 48027-48037, 2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37812497

RESUMO

Photosensitizers have emerged as cytotoxic reactive oxygen species (ROS) activators in photodynamic therapy (PDT), which induced cell apoptosis. As the major contributors to ROS and oxidative stress, mitochondria play an important role in cell apoptosis. Although there are many reports about near-infrared 4,4-difluoro-4-bora-3a,4a-diaza-s-indacene (BODIPY) as photosensitizers (PSs) for PDT, this kind of PS has rarely been used for treating mitochondrial function and choroidal neovascularization application at the same time. Herein, a novel near-infrared PS (BDP2) characterized by good water solubility, long wavelength excitation, and high ROS quantum yield has been made. Under near-infrared light irradiation, BDP2 would generate ROS with high yield, induce a mitochondrial morphology change, and trigger cell apoptosis by changing the fusion protein level. Deep investigation revealed that BDP2 can cause oxidative stress, break the balance between fusion and fission of mitochondrial dynamics protein through decreasing fusion protein MFN2 and OPA1 expression, and finally cause cell apoptosis. Due to these characteristics, the BDP2 PS was used to treat choroidal neovascularization in animal models and can inhibit neovascularization.


Assuntos
Neovascularização de Coroide , Fotoquimioterapia , Animais , Fármacos Fotossensibilizantes/farmacologia , Fármacos Fotossensibilizantes/uso terapêutico , Dinâmica Mitocondrial , Espécies Reativas de Oxigênio/metabolismo , Proteínas Mitocondriais , Neovascularização de Coroide/tratamento farmacológico
8.
Clin Cardiol ; 46(10): 1227-1233, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37537947

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is an established treatment option for heart failure patients. However, the implementation of triple-chamber pacemakers can be cost-prohibitive. His-Purkinje system pacing (HPSP) can also enable cardiac resynchronization, and it can be achieved with relatively inexpensive conventional pacemakers. HYPOTHESIS: This article aims to comparatively evaluate the cost of implanting devices in different CRT strategies to provide meaningful guidance for clinical decision-making by electrophysiologists. METHODS: Data was collected on the prices, designed life, and price/designed life of multiple mainstream models of CRT-P, CRT-D, dual-chamber pacemakers, and single-chamber pacemakers that were sold in the Chinese market in 2022. The prices, designed lives, and price/designed life of different pacemaker models were then compared. RESULTS: The costs of CRT-P and CRT-D (13008.44 ± 2752.30 USD and 22043.36 ± 3676.25 USD) were significantly higher than those of conventional pacemakers (dual-chamber: 11142.39 ± 4273.85 USD and single-chamber: 5634.28 ± 2032.80 USD) (p < .05). Additionally, the price/designed life of conventional pacemakers (dual-chamber: 839.63 ± 258.62 US dollar/year and single-chamber: 435.86 ± 125.44 US dollar/year) was significantly better than that of CRT-P and CRT-D (1386.91 ± 266.73 and 2585.53 ± 520.27 US dollar/year, respectively) (p < .05). CONCLUSION: Conduction system pacing (CSP)-based CRT is more cost-effective than BVP-based CRT. Furthermore, CSP-based CRT can achieve cardiac resynchronization with conventional pacemakers and may be a good option for HF patients who do not need defibrillation.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Marca-Passo Artificial , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Análise Custo-Benefício , Resultado do Tratamento
9.
Math Biosci Eng ; 20(7): 13415-13433, 2023 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-37501494

RESUMO

For wearable electrocardiogram (ECG) acquisition, it was easy to infer motion artifices and other noises. In this paper, a novel end-to-end ECG denoising method was proposed, which was implemented by fusing the Efficient Channel Attention (ECA-Net) and the cycle consistent generative adversarial network (CycleGAN) method. The proposed denoising model was optimized by using the ECA-Net method to highlight the key features and introducing a new loss function to further extract the global and local ECG features. The original ECG signal came from the MIT-BIH Arrhythmia Database. Additionally, the noise signals used in this method consist of a combination of Gaussian white noise and noises sourced from the MIT-BIH Noise Stress Test Database, including EM (Electrode Motion Artifact), BW (Baseline Wander) and MA (Muscle Artifact), as well as mixed noises composed of EM+BW, EM+MA, BW+MA and EM+BW+MA. Moreover, corrupted ECG signals were generated by adding different levels of single and mixed noises to clean ECG signals. The experimental results show that the proposed method has better denoising performance and generalization ability with higher signal-to-noise ratio improvement (SNRimp), as well as lower root-mean-square error (RMSE) and percentage-root-mean-square difference (PRD).


Assuntos
Algoritmos , Processamento de Sinais Assistido por Computador , Eletrocardiografia/métodos , Teste de Esforço , Razão Sinal-Ruído
10.
Dalton Trans ; 52(30): 10567-10573, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37458678

RESUMO

The development of a rapid and selective method for the identification of dipicolinic acid (DPA), a specific biomarker in Bacillus anthracis spores, is of great importance for the avoidance of anthrax infection. Herein, a chain-based EuIII metal-organic framework with the formula {[Eu3(BTDB)3(µ3-OH)3(H2O)]·solvents}n (JXUST-38, H2BTDB = (benzo[c][1,2,5]thiadiazole-4,7-diyl)dibenzoic acid) was obtained using 2-fluorobenzoic acid as the pH regulator. JXUST-38 exhibits good chemical and thermal stability and can specifically recognize DPA in N,N-dimethylformamide solution through luminescence enhancement and blue-shift effects with a detection limit of 0.05 µM. Furthermore, the significant luminescence enhancement and blue shift under UV lamps are obviously observable by the naked eye. The luminescence sensing mechanism is attributed to absorbance-induced enhancement between JXUST-38 and DPA. Test paper and mixed-matrix membrane based on JXUST-38 are designed for DPA detection. In addition, the feasibility of using JXUST-38 in biosensing is discussed in detail.

11.
Anal Chem ; 95(11): 4992-4999, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-36877827

RESUMO

A lanthanide-based three-dimensional metal-organic framework with excellent water, acid/base, and solvent stability, namely {[(CH3)2NH2]0.7[Eu2(BTDBA)1.5(lac)0.7(H2O)2]·2H2O·2DMF·2CH3CN}n (JXUST-29, H4BTDBA = 4',4‴-(benzo[c][1,2,5]thiadiazole-4,7-diyl)bis([1,1'-biphenyl]-3,5-dicarboxylic acid), Hlac = lactic acid), has been synthesized and characterized. Since the N atoms of the thiadiazole group will not coordinate with lanthanide ions, JXUST-29 has a free basic N-site accessible to small H+ ions, which allows it to be used as a promising pH fluorescence sensor. Interestingly, the luminescence signal was significantly enhanced, with an approximately 54-fold enhancement in the emission intensity when the pH value was increased from 2 to 5, which is the typical behavior of pH probes. In addition, JXUST-29 can also be used as a luminescence sensor to detect l-arginine (Arg) and l-lysine (Lys) in an aqueous solution through fluorescence enhancement and the blue-shift effect. The detection limits were 0.023 and 0.077 µM, respectively. In addition, JXUST-29-based devices were designed and developed to facilitate detection. Importantly, JXUST-29 is also capable of detecting and sensing Arg and Lys in living cells.


Assuntos
Elementos da Série dos Lantanídeos , Estruturas Metalorgânicas , Estruturas Metalorgânicas/química , Lisina , Elementos da Série dos Lantanídeos/química , Íons , Água/química , Concentração de Íons de Hidrogênio
12.
Analyst ; 148(5): 1016-1023, 2023 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-36723185

RESUMO

Abnormal levels of thiols in cysteine (Cys) have been shown to be associated with growth retardation, skin lesions, and neurotoxicity in humans. Herein, we designed and synthesized a rare earth upconversion luminescent (UCL) nanocomposite probe UCNP-PEG-NOF1 for the UCL detection of Cys using NOF1 developed by our group as a Cys probe. The core structure of rare earth nanoparticles can absorb light at 980 nm and convert it into visible light. The detection principle of Cys was based on the change in absorption peak before and after the reaction between NOF1 and Cys, as well as the change in UCL intensity. The rare earth nanocomposite in the probe could be excited by near-infrared light and had low background fluorescence and strong penetration ability; thus, the probe was successfully employed to specifically and sensitively detect Cys with a low background signal. Overall, the developed UCNP-PEG-NOF1 probe had good selectivity and high sensitivity for Cys; its detection limit was as low as 83 nM.


Assuntos
Cisteína , Nanopartículas , Humanos , Luminescência , Transferência de Energia , Raios Infravermelhos
13.
BMC Pulm Med ; 23(1): 55, 2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36747237

RESUMO

BACKGROUND: The risk factors for osteoporosis and its prognostic value in patients with bronchiectasis is not well characterized. We explored the risk factors for osteoporosis and its prognostic impact in hospitalized non-cystic fibrosis bronchiectasis (NCFB) patients in Southeast China. METHODS: This observational cohort study consecutively enrolled 179 hospitalized patients with NCFB bronchiectasis between 2017 and 2021. The risk factors and the impact of osteoporosis on all-cause mortality were assessed. RESULTS: 21.2% (38/179) of hospitalized NCFB patients were diagnosed with osteoporosis. Patients with osteoporosis had more severe symptoms (assessed by chronic airway assessment test, CAT, median 22 vs. 17, P = 0.017), poorer quality of life (assessed by St. George Respiratory Questionnaires, SQRC, median 42 vs. 27, P = 0.007), more severe disease stage (assessed by bronchiectasis severity index, BSI, median 14 vs. 11, P = 0.02), more comorbidities (assessed by Bronchiectasis Aetiology Comorbidity Index, BACI, median 5 vs. 4, P = 0.021) than patients without. Age, female sex, anemia, post-infection, and history of regular inhaled corticosteroid treatment were independent risk factors for osteoporosis in those patients. 21 patients (11.7%) died over a median follow-up period of 32 months. The all-cause mortality in NCFB patients with osteoporosis [28.94% (11/38)] was significantly higher than those without osteoporosis [7.09% (10/141)] [hazard ratio (HR) 5.34, 95% confidence interval (CI) 2.26-12.67, P < 0.001]. After adjusting for BSI and other confounding factors, osteoporosis was still independently associated with all-cause mortality in hospitalized NCFB patients (HR 4.29, 95% CI 1.75-10.49, P < 0.001). CONCLUSIONS: Osteoporosis had an independent effect on all-cause mortality in hospitalized NCFB patients. Management of comorbidities, including bone health, is a critical aspect of treating NCFB patients.


Assuntos
Bronquiectasia , Fibrose Cística , Osteoporose , Feminino , Humanos , Prognóstico , Qualidade de Vida , Bronquiectasia/complicações , Bronquiectasia/epidemiologia , Bronquiectasia/diagnóstico , Osteoporose/complicações , Osteoporose/epidemiologia , Fatores de Risco
14.
Ann Noninvasive Electrocardiol ; 28(2): e13010, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36165099

RESUMO

Atrial flutter (AFL) is the second most common atrial tachyarrhythmia after atrial fibrillation. Catheter ablation (CA) for typical AFL is well-established and has a high success rate and adequate safety. However, sick sinus syndrome (SSS) occasionally occurs when long-term, persistent AFL is terminated by ablation. Sinus node function cannot be assessed during AFL, and the preoperative prediction of underlying SSS has not yet been investigated. When this situation occurs, pacemaker implantation is often necessary. Here, we report a case of SSS after persistent AFL CA.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Humanos , Flutter Atrial/etiologia , Flutter Atrial/cirurgia , Síndrome do Nó Sinusal/cirurgia , Eletrocardiografia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Resultado do Tratamento
15.
Am J Cardiol ; 187: 1-9, 2023 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-36459730

RESUMO

Real-time 3-dimensional echocardiography combined with speckle tracking was used in this study. A total of 90 patients with normal left ventricular ejection fraction were divided into 3 groups according to the pacing site: left bundle branch area pacing (LBBAP), right ventricular septal pacing (RVSP) or right ventricular apical pacing (RVAP). Procedure duration (90 ± 18 vs 61 ± 6.6 vs 58 ± 5.6 minutes, p = 0.015), Fluoroscopy duration (15.5 ± 5.4 vs 4.8 ± 2.2 vs 4 ± 1.9 minutes, p = 0.004), and ventricular capture threshold at implantation (0.8 ± 0.3 vs 0.6 ± 0.2 vs 0.6 ± 0.1 V, p = 0.002) were significantly increased in patients that received LBBAP compared with RVSP or RVAP. At 4 weeks of follow-up, brain natriuretic peptide levels were significantly lower (22 [12 to 59] vs 135 [86 to 231] vs 235 [147 to 428] pg/ml, p = 0.04), paced QRS duration was significantly shorter (115 ± 26 vs 134 ± 28 vs 157 ± 29 ms, p = 0.012), and global longitudinal strain (-19.4 ± 2.4 vs -19.3 ± 3.4 vs -17.3 ± 3.5%, p = 0.026) and systolic dyssynchrony index (2.5 ± 0.3 vs 5.9 ± 0.9 vs 7.7 ± 1.2, p = 0.001), longitudinal absolute maximum difference of time to peak strain (17 [6 to 68] vs 117 [71 to 173] vs 126 [79 to 178] ms, p <0.0001), and circumferential absolute maximum difference of time to peak strain (76 [32 to 129] vs 148 [117 to 208] vs 161 [118 to 266] ms, p = 0.005) were significantly lower in patients that received LBBAP compared with RVSP or RVAP. In conclusion, LBBAP can provide a more physiological ventricular activation pattern than RVSP or RVAP and results in good left ventricular electrical and mechanical synchronization.


Assuntos
Ecocardiografia Tridimensional , Marca-Passo Artificial , Humanos , Fascículo Atrioventricular , Estimulação Cardíaca Artificial/métodos , Volume Sistólico , Função Ventricular Esquerda/fisiologia , Eletrocardiografia/métodos
16.
BMC Cardiovasc Disord ; 22(1): 549, 2022 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-36526970

RESUMO

BACKGROUND: In recent years, the difference in outcomes of radiofrequency catheter ablation (RFCA) in persistent atrial fibrillation patients has risen. In particular, biological sex seems involved in a different response to the AF ablation procedure. In our study, we analyzed the AF recurrences after RFCA assessing the other association between male/female patients with the outcomes. METHODS: We enrolled 106 patients (74.5% men) with persistent atrial fibrillation with scheduled follow-up. The baseline clinical characteristics and AF recurrence after RFCA were compared between men and women. Cox regression analyses were performed to determine the risk predictors of AF recurrence. RESULTS: The proportion of RFCA in women was lower than that in men. Men with persistent AF were younger than women (58.6 ± 10.4 years vs. 65.1 ± 8.7 years, respectively; p = 0.003). The left atrium (LA) diameter was higher in males (43.7 ± 4.6 mm vs. 41.3 ± 5.5 mm; p = 0.028), and the level of left heart ejection fraction (LVEF) was higher in females (59.4 ± 6.9% vs. 64.1 ± 5.5%; p = 0.001). Sex differences in AF recurrence after RFCA were significant during the median 24.4-month (interquartile range: 15.2-30.6 months) follow-up period, and the recurrence rate of AF in women was significantly higher than that in men (p = 0.005). Univariable Cox regression analysis showed that female sex was a risk factor for persistent AF recurrence after RFCA [HR: 2.099 (1.087-4.053)]. Univariate Cox regression analysis revealed that non-PV ablation not associated with AF recurrence [HR: 1.003 (0.516-1.947)]. CONCLUSION: In a monocentric cohort of persistent AF patients, the female biological sex was associated with a higher risk of AF recurrence after RFCA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Feminino , Humanos , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Caracteres Sexuais , Recidiva , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
17.
Turk J Med Sci ; 52(4): 1103-1110, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36326398

RESUMO

BACKGROUND: Patients with atrial fibrillation (AF) and coronary stenting had a poor prognosis. This study aimed to assess the accuracy of CHA2DS2-VASc score for predicting and grading adverse clinical outcomes in this population. METHODS: We reviewed the clinical data of all patients with previously documented nonvalvular AF who underwent coronary stenting between January 2010 and June 2015 in 12 hospitals of Beijing, China. The study population was divided into three groups: 1) Low CHA2DS2-VASc score, ≦ 2 points, 2) Intermediate score, 3-4 points, and 3) High score, ≧ 5 points. Major adverse cardiac/cerebrovascular events (MACCE) were defined as a composite of all-cause death, nonfatal myocardial infarction, repeat revascularization and ischemic stroke/systemic thromboembolism (IS/SE). RESULTS: A total of 2394 patients (men: 72.3% vs. women: 27.7%, median age: 67 years) were included, with the CHA2 DS2-VASc score of 3.6 ± 1.6. The median follow-up duration was 36.2 months. All-cause mortality increased 3 folds from the low score (4.8%) to the high score group (15.8%). The high score group had more IS/SE (7.4%) and MACCE (26.3%). The CHA2 DS2-VASc score ≧ 5 points was independently associated with all-cause death (hazard ratio [HR]: 2.303, 95% confidence interval [CI]: 1.492- 3.555), IS/SE (HR: 4.169, 95% CI: 2.216-7.845) and MACCE (HR: 1.468, 95% CI: 1.113-1.936) on multivariate Cox proportional hazards regression. The area under the receiver operating characteristic curve of the CHA2DS2-VASc score was 0.644 (95% CI: 0.624-0.663) for all-cause death, 0.647 (95% CI: 0.627-0.666) for IS/SE, and 0.592 (95% CI: 0.572-0.611) for MACCE. DISCUSSION: CHA2DS2-VASc score was a reliable prognostic indicator in patients with AF and coronary stenting.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Masculino , Humanos , Feminino , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , Prognóstico , Acidente Vascular Cerebral/complicações , Medição de Risco , Fatores de Risco
18.
Front Cardiovasc Med ; 9: 1010443, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36386356

RESUMO

This study aimed to establish a model that predicts atrial fibrillation (AF) recurrence after catheter ablation using clinical risk factors and biomarkers. We used a prospective cohort study, including 230 consecutive persistent AF patients successfully treated with catheter ablation from January 2019 to December 2020 in our hospital. AF recurrence was followed-up after catheter ablation, and clinical risk factors and biomarkers for AF recurrence were analyzed. AF recurred after radiofrequency ablation in 72 (31%) patients. Multiple multivariate logistic regression analysis demonstrated that tissue inhibitor of metalloproteinase-1 (TIMP-1) and left atrium diameter (LAd) were closely associated with AF recurrence. The prediction model constructed by combining TIMP-1 and LAd effectively predicted AF recurrence. Additionally, the model's performance discrimination, accuracy, and calibration were confirmed through internal validation using bootstrap resampling (1,000 times). The model showed good fitting (Hosmer-Lemeshow goodness chi-square 3.76138, p = 0.926) and had a superior discrimination ability (the area under the receiver operation characteristic curve0.917; 95% CI 0.882-0.952). The calibration curve showed good agreement between the predicted probability and the actual probability. Moreover, the decision curve analysis (DCA) showed the clinical useful of the nomogram. In conclusion, our predictive model based on serum TIMP-1 and LAd levels could predict AF recurrence after catheter ablation.

19.
Front Cardiovasc Med ; 9: 961914, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36312240

RESUMO

Background: Tissue inhibitor of metalloproteinase-1 (TIMP-1) levels is strongly associated with cardiac extracellular matrix accumulation and atrial fibrosis. Whether serum levels of TIMP-1 are associated with atrial fibrillation (AF) recurrence following radiofrequency catheter ablation (RFCA) remains unknown. Materials and methods: Serum TIMP-1 levels of patients with AF before they underwent initial RFCA were measured using ELISA. Univariate and multivariate-adjusted Cox models were constructed to determine the relationship between TIMP-1 levels and AF recurrence. Multivariate logistic regression analyses were performed to determine predictors of AF recurrence. Results: Of the 194 enrolled patients, 61 (31.4%) had AF recurrence within the median 30.0 months (interquartile range: 16.5-33.7 months) of follow-up. These patients had significantly higher baseline TIMP-1 levels than those without AF recurrence (129.8 ± 65.7 vs. 112.0 ± 51.0 ng/ml, P = 0.041). The same was true of high-sensitivity C-reactive protein (3.9 ± 6.0 vs. 1.9 ± 2.8 ng/ml, P = 0.001). When a TIMP-1 cutoff of 124.15 ng/ml was set, patients with TIMP-1 ≥ 124.15 ng/ml had a higher risk of recurrent AF than those with TIMP-1 < 124.15 ng/ml (HR, 1.961, 95% CI, 1.182-2. 253, P = 0.009). Multivariate Cox regression analysis revealed that high TIMP-1 was an independent risk factor for AF recurrence. Univariate Cox regression analysis found that substrate modification surgery does not affect AF recurrence (P = 0.553). Subgroup analysis revealed that female sex, age < 65 years, hypertension (HTN), body mass index (BMI) ≥ 24 kg/m2, CHA2DS2-VASc score < 2, HAS-BLED score < 3, and EHRA score = 3 combined with high TIMP-1 level would perform well at predicting AF recurrence after RFCA. Conclusion: Elevated preoperative TIMP-1 levels are related to a higher risk of AF recurrence and can independently predict AF recurrence following RFCA.

20.
Anal Chem ; 94(34): 11881-11888, 2022 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-35973089

RESUMO

Liver and kidney injury caused by drug toxicity is a serious threat to human health. Acetaminophenol (APAP), as a common antipyretic and analgesic drug, inevitably causes injury. When it is overused, hypochlorous acid (HClO) is excessively generated due to metabolic abnormalities, resulting in the accumulation of HClO in the mitochondria of liver and kidney tissues and causing damage. In this study, we designed a series of HClO responsive ratiometric chemdosimeter NRH-X (NRH-O, NRH-S, and NRH-C) to evaluate liver and kidney injury, and found that NRH-O has a specific sensitive response to HClO. NRH-O can not only monitor the variations of endogenous HClO content of living cells by fluorescence ratio changes in the mitochondria but also detect the upregulation of HClO induced by APAP. In addition, NRH-O can also be used for anatomic diagnosis of liver and kidney injury by fluorescence ratio imaging of HClO in the tissues of inflammatory mice.


Assuntos
Acetaminofen , Ácido Hipocloroso , Acetaminofen/metabolismo , Acetaminofen/toxicidade , Animais , Corantes Fluorescentes/metabolismo , Humanos , Ácido Hipocloroso/metabolismo , Rim/metabolismo , Fígado/metabolismo , Camundongos , Mitocôndrias/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...